Folded Flight Path
LECO’s patented Folded Flight Path® (FFP®) technology has celebrated over ten years of mass spectrometry breakthroughs. This ingenious concept uses multi-reflecting technology to strip away the oversized flight tubes from traditional high resolution Time-of-Flight (TOF) mass spectrometers and packs an impressive resolving power of 25,000 into a surprisingly small footprint. Ultra High Resolution mode enables the FFP instruments to reach resolving powers of over 50,000 with flight paths equivalent of 40 m without a single increase in lab space.
What is the Folded Flight Path?
TOF mass spectrometry has several major advantages in the field of mass spectrometry.
- Unlimited mass range: The mass analyzer itself is not a limiting factor for the mass range of ions.
- Full mass range spectra: All ion masses present in the extraction region are recorded in the single spectrum.
- No spectral skewing: There is no scan time, as time can be measured extremely fast, which results in no skewing.
The resolving power of a TOF mass spectrometer has always been determined by how narrow the peak widths are and how long the ions’ flight times are. With peak widths essentially limited by real-world constraints, the only way to significantly increase resolving power is to increase the flight time.
Traditional high resolution TOF mass spectrometers use multi-reflections of ions using mirrors and grids defining electrical fields of different strengths within the reflection. Even the most transparent grids will lead to significant ion losses, with more reflections weakening the resulting signals further.
The FFP went in a different direction.
Using a series of planar gridless mirrors and an array of Einzel focusing electrostatic lenses, the FFP is able to direct ions through 16 lenses and 32 reflections, creating a 20 m ion path within a 30 in x 6 in x 4 in vacuum chamber. In Ultra High Resolution mode, the ions are reversed at the end and sent through the array again, doubling the flight path and the resolving power.
Instrument Portfolio
Gain more insight with this exciting resource
Folded Flight Path with Pegasus GC-HRT
Explore this resourceNews or Stories
LECO is celebrating ten years of the Folded Flight Path! Learn more about this revolutionary breakthrough for high-resolution TOF technology!
Posters and Presentations
- Increasing Resolution in Multi-Reflecting TOFMS with Folded Flight Path Recent advancements in High Resolution Time-of-Flight Mass Spectrometry based on the Multi-Reflecting design of LECO's Folded Flight Path mass analyzers are presented.